Nassatropin®
Results:
11.36 IU – (113.6% declared content)
Research Comment:
The tested sample was applied in an amount of 3ul to the BioBasic 8 Thermo Scientific column. During the course of the analysis method
linear gradient in solutions of H20 and Acetonitrile with the addition of 0.1% trifuluoroacetic acid appeared
peak of the substance you are looking for. Its concentration after comparison to the standard chromatogram is 3.75 mg. Height
measurement error is +- 0.05mg.
Stanozolol
Results:
49,95 mg – (99,9% declared content)
Research Comment:
The tested sample was applied in an amount of 3ul to the BioBasic 8 Thermo Scientific column. During the course of the analysis method
linear gradient in solutions of H20 and Acetonitrile with the addition of 0.1% trifuluoroacetic acid, a peak appeared
the substance you are looking for. Its concentration after comparison to the standard chromatogram is 49.95mg/ml. Height
measurement error is +- 1 mg.
Trestolone Acetate
Results:
53,78 mg – (107.56% declared content)
Research Comment:
The tested sample was applied in an amount of 3ul to the BioBasic 8 Thermo Scientific column. During the course of the analysis method
linear gradient in solutions of H20 and Acetonitrile with the addition of 0.1% trifuluoroacetic acid, a peak appeared
the substance you are looking for. Its concentration after comparison to the standard chromatogram is 53.78 mg/ml. Height
measurement error is +- 1 mg.
TESTOSTERONE ENANTHATE
Results:
267,33 mg – (106.93% declared content)
Research Comment:
The tested sample was applied in an amount of 3ul to the BioBasic 8 Thermo Scientific column. During the course of the analysis method
linear gradient in solutions of H20 and Acetonitrile with the addition of 0.1% trifuluoroacetic acid, a peak appeared
the substance you are looking for. Its concentration after comparison to the standard chromatogram is 267.33mg/ml. Height
measurement error is +- 1 mg.
METHENOLONE ENANTHATE
Results:
104,56 mg – (104,56% declared content)
Research Comment:
The tested sample was applied in an amount of 3ul to the BioBasic 8 Thermo Scientific column. During the course of the analysis method
linear gradient in solutions of H20 and Acetonitrile with the addition of 0.1% trifuluoroacetic acid, a peak appeared
the substance you are looking for. Its concentration after comparison to the standard chromatogram is 104.56mg/ml. Height
measurement error is +- 1 mg.
Methandienone
Results:
9,69 mg – (96.9% declared content)
Research Comment:
The tested sample was applied in an amount of 3ul to the BioBasic 8 Thermo Scientific column. During the course of the analysis method
linear gradient in solutions of H20 and Acetonitrile with the addition of 0.1% trifuluoroacetic acid did not appear
peak of the substance you are looking for. The concentration of the found substance after comparison to the standard chromatogram is:
9.69mg/tab. The measurement error is +- 0.05mg.
oXANDROLONE
Results:
9,72 mg – (97,2% declared content)
Research Comment:
The tested sample was applied in an amount of 6ul to the BioBasic 8 Thermo Scientific column. During the course of the analysis method
linear gradient in solutions of H20 and Acetonitrile with the addition of 0.1% trifuluoroacetic acid did not appear
peak of the substance you are looking for. The concentration of the found substance after comparison to the standard chromatogram is:
9.72mg/tab. The measurement error is +- 0.05mg.